TCL HVAC Middle East — Product & Company Knowledge Base
A single plain-text reference for chat assistants and search engines: company facts, every product line with its rated figures, application guidance, and answers to common questions. Figures come from TCL global product pages and vary by model and region.
Company facts
- TCL was founded in 1981 and serves more than 160 countries and regions.
- TCL Air Conditioner is No.2 among China’s AC exporters (13.81 million units), No.1 worldwide in fresh-air AC sales, and No.1 in export growth among China’s top-3 AC exporters.
- TCL Air Conditioner operates 12 global manufacturing bases with more than 38 million units of annual capacity and over 1,000 R&D experts.
- TCL commercial air-conditioning production lines: indoor units 683,000 sets/year, outdoor units 500,000 sets/year, VRF 27,000 sets/year.
- TCL is a Worldwide Olympic and Paralympic Partner of the IOC for Home Audiovisual Equipment and Appliances through 2032.
- Product certifications published for TCL commercial products include CE, CB, LVD, ErP, RoHS, REACH, SASO, SAA, WaterMark, ISED and SG Ready; they vary by product, model and destination market and must be confirmed per project.
Products
VRF Systems (3 – 104 HP)
TMV7 Smart and TMV6 platforms, matched indoor units and BMS-ready controls for towers, hotels, malls and compounds.
TCL TMV7 Smart — Flagship cooling & heating VRF
TCL’s flagship VRF platform for large commercial buildings. Single modules of 14–26 HP combine into systems of up to 104 HP serving as many as 80 indoor units, with AI energy optimisation, multi-level backup and a 6-step generator mode for sites running on standby power.
- Capacity: 14–26 HP / module · up to 104 HP
- Cooling operating range: −15 → 56 °C
- Heating down to: −30 °C
- Max. system capacity: 104 HP
- Indoor units per system: 80
- AI annual energy saving: 20%
- Outdoor standby power: 1 W
- Refrigerant-cooled inverter: 360° dual-tube refrigerant cooling draws heat away from the main control board and inverter module. In testing, module temperature fell by 20 °C — the difference between derating and running at full load in a Gulf summer.
- Multiple backup operation: If one outdoor module fails it is isolated from system communication while the rest keep running; on dual-fan units the second fan takes over instantly.
- AI energy saving: A self-optimising control loop senses multiple parameters and matches output to real-time load by adjusting frequency and airflow, for up to 20% annual energy savings.
- 6-step generator mode: Cap capacity in six steps from 40% to 100% from the wired or remote controller so the system stays within generator limits.
- EVI compressor & U-shaped coil: Enhanced vapour injection sustains cooling at 55 °C ambient, while the three-sided U-shaped heat exchanger adds 40% effective area over a single-row design.
- Faster commissioning: Automatic indoor-unit addressing, one-button test run, emergency IDU maintenance mode and auto-restart after power cuts cut site time and call-backs.
Typical applications: Hotels & Hospitality, Malls & Retail, Offices & Towers.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tmv7-smart
TCL TMV6+ ECOC — Cooling-only VRF rated to 60 °C
A cooling-only VRF engineered around Gulf conditions: stable operation from −15 °C up to 60 °C ambient, triple backup, automatic dust removal and total piping runs of up to 1,100 m. Modules from 8 to 36 HP.
- Capacity: 8–36 HP
- Cooling operating range: −15 → 60 °C
- Max. cooling ambient: 60 °C
- Total piping length: 1,100 m
- Backup: compressor, fan, module: 3×
- Generator mode, 6 levels: 40–90%
- Wraparound refrigerant radiator: A refrigerant radiator wrapped around the inverter module carries heat away steadily, keeping the electronics reliable when the outdoor unit sits in direct sun.
- Triple backup: Compressor backup on twin-compressor units, emergency fan-motor operation on dual-fan units and outdoor-module backup in multi-module systems.
- Automatic dust removal: A built-in auto dust-removal function keeps the outdoor coil clear, protecting heat exchange and efficiency through sandstorm season.
- Offline AI algorithm: Built-in AI continuously optimises temperature and efficiency and drives a self-adapting compressor — entirely offline, so performance and data privacy never depend on the internet.
- Generator mode: Six capacity levels from 40% to 90% keep current draw within generator limits; the system returns to 100% automatically when grid power is restored.
- 1,100 m piping & BMS gateways: Long total piping and high drop give freedom on towers and spread-out sites; BMS gateways connect the system to building management.
Typical applications: Hotels & Hospitality, Malls & Retail, Offices & Towers, Halls & Warehouses.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tmv6-plus-ecoc
TCL TMV6+ Super — Full-DC cooling & heating VRF with EVI
A full-DC inverter cooling and heating VRF from 8 to 32 HP per module. Enhanced vapour injection, refrigerant-cooled electronics and the 1,100 m piping design of the TMV6+ platform, with cooling from −15 °C to 56 °C and heating down to −30 °C.
- Capacity: 8–32 HP
- Cooling operating range: −15 → 56 °C
- Heating down to: −30 °C
- Max. cooling ambient: 56 °C
- Min. heating ambient: −30 °C
- Total piping length: 1,100 m
- Vapour-injection compressor: EVI
- Enhanced vapour injection: Injecting part of the gaseous refrigerant into the compression chamber raises capacity at the extremes and lowers discharge temperature.
- Refrigerant + air heat dissipation: A refrigerant radiator and forced-air cooling protect the inverter module for stable, safe operation at high ambient.
- Layered backup: Compressor, fan-motor and outdoor-module backup keep the building cooled while a fault is serviced.
- Anti-adversity start: When strong wind spins the outdoor fan backwards, the controller stops it and restarts in the forward direction — avoiding damaging start-up current.
Typical applications: Hotels & Hospitality, Offices & Towers, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tmv6-plus-super
TCL TMV6 Master — Proven full-DC VRF workhorse
The TMV6 Master balances performance and project budget: full-DC inverter modules from 8 to 30 HP, refrigerant-cooled drives, layered backup and TCL Wi-Fi control, with up to 1,100 m of piping for tall and spread-out buildings.
- Capacity: 8–30 HP
- Cooling operating range: −15 → 56 °C
- Heating down to: −25 °C
- Max. cooling ambient: 56 °C
- Module range: 8–30 HP
- Total piping length: 1,100 m
- TCL Wi-Fi control system: Wi-Fi
- Refrigerant radiator: Keeps the inverter module cool and the unit electrically reliable when working in high-temperature environments.
- Compressor, fan & module backup: A failed compressor, fan motor or outdoor module is bypassed and the remaining capacity keeps running.
- Wi-Fi & BMS: TCL Wi-Fi control for owners and BMS gateways for facility teams.
Typical applications: Hotels & Hospitality, Offices & Towers, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tmv6-master
TCL TMV6 Eco Mini — Mini VRF for villas & small offices
A compact mini-VRF that replaces a row of split outdoor units with one: full-DC inverter rotary compressor, DC fan motor and multi-connection to ducted, cassette and wall indoor units — ideal for villas, apartments and small commercial spaces.
- Capacity: 3–6 HP
- Cooling operating range: −20 → 55 °C
- Heating down to: −20 °C
- Max. cooling ambient: 55 °C
- Capacity range: 3–6 HP
- One ODU, many rooms: 1 → N
- Inverter compressor & fan: Full DC
- Full-DC inverter platform: High-efficiency DC inverter rotary compressor paired with a DC fan motor.
- Saves façade and roof space: Compared with one-to-one splits, a single mini-VRF outdoor unit frees façade and roof area and simplifies the villa layout.
- Stable in heat and cold: Cooling from −20 °C to 55 °C with intelligent defrosting for stable heating.
Typical applications: Offices & Towers, Villas & Compounds, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tmv6-eco-mini
TCL VRF Indoor Units — One family, every ceiling
Matched indoor units for TCL VRF: 360° Q8 cassette, compact cassette, one- and two-way cassettes, low-ESP slim duct, free-ESP duct, high static pressure duct and wall-mounted units — so one system can serve lobbies, guest rooms and back-of-house alike.
- Capacity: 8 indoor unit types
- Indoor unit types: 8
- Fan-speed levels: 7
- Slim duct body: 245 mm
- Inverter fan motors: DC
- 360° Q8 cassette: New panel design, large air volume, 7-level fan speed and 360° wide-angle supply, with a standard float switch for timely warning.
- Slim & free-ESP ducts: Constant air volume, a 245 mm body, two air-return options, ceiling or floor concealment and fresh-air connection.
- High static pressure duct: Ultra-high static pressure for long duct runs and varied outlet forms that disappear into the interior design.
- Wall-mounted: Ultra-quiet, slim and easy to maintain, with a long-lasting filter design for guest rooms and offices.
Typical applications: Hotels & Hospitality, Malls & Retail, Offices & Towers, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/vrf-indoor-units
TCL Controls & BMS Gateways — From one room to a whole campus
Remote and wired controllers, 7- and 10-inch central controllers, Wi-Fi modules and Modbus / BACnet BMS gateways connect TCL systems to building management, billing platforms and mobile apps.
- Capacity: Modbus · BACnet · Wi-Fi
- BMS gateway: BACnet
- RS485 integration: Modbus
- Central touch controller: 10″
- Wi-Fi remote control: App
- BMS gateways: Modbus and BACnet gateways expose TCL VRF and light-commercial systems to third-party BMS for monitoring and control.
- Central controllers: 7- and 10-inch touch controllers for facility teams to schedule, group and lock units across a building.
- Dry contact for hospitality: Units can be switched by keycard holders, window contacts or the fire-alarm system for energy control and safety.
- Wired, remote & Wi-Fi: Wired controllers, remote controllers and Wi-Fi modules for occupants, with app control for owners.
Typical applications: Hotels & Hospitality, Malls & Retail, Offices & Towers, Halls & Warehouses.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/controls-bms
Light Commercial (12K – 60K Btu/h · 10 HP)
Ducted, cassette, ceiling & floor and floor-standing systems with high-ambient outdoor units for retail, offices, villas and F&B.
TCL Tropical High ESP Duct — Ducted split, stable cooling at 60 °C
Built for tropical and desert climates, this concealed ducted split delivers stable cooling at 60 °C ambient with up to 200 Pa external static pressure, constant air volume and a 245 mm slim body. Twin and triple systems, Wi-Fi, BMS and dry-contact control are supported.
- Capacity: 18K–60K Btu/h
- Rated cooling ambient: 60 °C
- Stable cooling ambient: 60 °C
- External static pressure: 200 Pa
- Slim body (18–36K): 245 mm
- Piping length · 40 m lift: 80 m
- Precise ±1 °C control: Full-DC inverter design with a high-precision electronic expansion valve holds the set temperature within ±1 °C.
- 200 Pa & constant air volume: Up to 200 Pa ESP on 36–55K models supports long ducts; the fan motor adapts to duct resistance to keep airflow constant.
- Healthier air: Evaporator self-cleaning, an optional silver-ion and activated-carbon health filter and an optional fresh-air module.
- Service-friendly: Motor removal from below, a two-screw control board, side-pull filter, optional 1,200 mm condensate pump and refrigerant recovery into the outdoor condenser.
- Twin / triple systems: One outdoor unit can drive two or three indoor units that switch together — ideal for open-plan spaces.
Typical applications: Malls & Retail, Offices & Towers, Villas & Compounds, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/tropical-high-esp-duct
TCL 200 Pa High Static Ducted System — Long-throw ducting for halls & large spaces
A full-DC inverter ducted system with 200 Pa high static pressure and up to 20 m of extendable ductwork for warehouses, halls and large open spaces. R32 refrigerant, A++ cooling efficiency, T-AI energy saving and stable operation from −25 °C to 58 °C.
- Capacity: 24K–55K Btu/h
- Rated cooling ambient: 58 °C
- Refrigerant: R32
- High static pressure: 200 Pa
- Extendable duct: 20 m
- Stable operation ambient: 58 °C
- Cooling energy rating: A++
- Adjustable static pressure: Highly efficient motor and optimised air path overcome duct resistance for strong, even airflow to every corner.
- BMS & Airzone ready: Matches BMS systems and Airzone zoning, with Wi-Fi and dry-contact control.
- 56 °C self-cleaning & OTA: High-temperature coil self-cleaning, easy refrigerant recovery and over-the-air updates.
Typical applications: Malls & Retail, Offices & Towers, Halls & Warehouses.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/high-static-ducted-system
TCL PowerIN 360° Round Cassette — Design-led circular cassette
A circular, bladeless cassette that turns the ceiling into a design element. A 200 mm slim body, 2,100 m³/h airflow, dual-ring 360° distribution and 27 dB(A) quiet operation suit hotel lobbies, premium retail and meeting spaces.
- Capacity: 18K–45K Btu/h
- m³/h airflow: 2,100
- Quiet operation: 27 dB(A)
- Slim body: 200 mm
- Dual-ring airflow: 360°
- Elevating panel & LED ring: The panel rises during operation for a sleek bladeless look and drops flush when off; the LED ring changes colour with the operating mode.
- Shower-style airflow: Dual rings descend 60 mm to create 360° distribution; air glides 4 m along the ceiling before settling gently.
- Three easy-maintenance designs: Detachable fan motor, 3-step PCB access and a built-in pump with 1,200 mm lift.
- Bipolar ionisation (optional): Active ion clusters neutralise airborne pathogens — 99% removal of Influenza A (H1N1) in third-party testing.
Typical applications: Hotels & Hospitality, Malls & Retail, Offices & Towers.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/round-cassette
TCL 360° Air Outlet Cassette — Four-way cassette with 360° outlet
A 360° air-outlet ceiling cassette for open-plan offices, showrooms and restaurants. Arc louvres sweep 0–85°, an optional soft-wind panel removes draughts and a 1,200 mm condensate pump with water-full protection simplifies installation.
- Capacity: 18K–60K Btu/h
- Air outlet: 360°
- Louvre swing: 0–85°
- Pump lift: 1,200 mm
- Wi-Fi · BMS · dry contact: BMS
- Soft-wind panel (optional): Diffuses airflow for draught-free comfort in spaces where people sit for long periods.
- Cool from above, warm from below: Wide arc-louvre swing sends cool air down from the ceiling and pushes warm air to the floor.
- Fresh-air knock-out & easy filter: A reserved knock-out connects a fresh-air duct; the filter detaches quickly for cleaning.
Typical applications: Malls & Retail, Offices & Towers, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/cassette
TCL One-Way Cassette — 130 mm slimline for tight ceilings
At just 130 mm, the one-way cassette fits ceilings where nothing else will. Coanda airflow with golf-ball dimple louvres throws air 10 m without draughts, AI Energy Saving 2.0 trims consumption by up to 38%, and 18K/24K models cool strongly at 56 °C ambient.
- Capacity: 12K–24K Btu/h
- Rated cooling ambient: 56 °C
- Body height: 130 mm
- Air throw: 10 m
- AI energy saving (TCL lab): 38%
- Strong cooling (18K/24K): 56 °C
- Anti-direct airflow: Dimpled louvres and the Coanda effect lift the air stream for a wind-free comfort zone below 0.3 m/s.
- Two-step filter, two-step PCB: One-key lifted filter, optional automatic lift grille and front-panel PCB access cut service time.
- Full-system self-cleaning: High-temperature indoor self-cleaning plus reverse-fan dust blowing on the outdoor unit.
- Modbus for up to 255 units: Modbus integration lets up to 255 indoor units report to a building management system.
Typical applications: Hotels & Hospitality, Offices & Towers, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/one-way-cassette
TCL Ceiling & Floor — Convertible, with a 20 m air throw
A convertible ceiling-or-floor unit with a cross-flow fan, 230 mm slim body and 20 m ultra-long air supply for restaurants, majlis rooms, showrooms and clinics. Two-way drainage and a clear LED display simplify installation and service.
- Capacity: 18K–60K Btu/h
- Air supply distance: 20 m
- Slim body: 230 mm
- Fan speeds: 7
- Airflow: 3D
- Flexible installation: Ceiling-suspended or floor-mounted, with condensate drainage from the left or right.
- 3D airflow, 7 speeds: Cross-flow fan blades and seven-gear speed control reach deep, wide rooms evenly.
- Reliable & readable: Power-off memory, rapid start, multiple protections and an LED display for temperature and error codes.
Typical applications: Malls & Retail, Villas & Compounds, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/ceiling-floor
TCL Floor Standing 10 HP — Big-space cooling with liquid-cooled electronics
A 10 HP floor-standing unit for halls, showrooms and warehouses: 4,700 m³/h airflow, an 18 m air throw and 120° wide-angle supply. A liquid-cooled control box keeps it running at 60 °C outdoors, with triple protection against moisture, water and dust.
- Capacity: 10 HP
- Rated cooling ambient: 60 °C
- m³/h airflow: 4,700
- Air throw: 18 m
- Stable outdoor ambient: 60 °C
- AI energy saving: 20%
- Liquid-cooled TEC control box: Liquid cooling keeps the electrics stable at 60 °C outdoor temperature; the box is sealed against moisture, water and dust and isolated from the evaporator.
- Self-developed drive: DC inverter compressor and fan with TCL’s own 180° sinusoidal-wave VFD for smooth, efficient control.
- Dust handled at both ends: A washable quick-release filter indoors, 58 °C deep cleaning, and reverse dust removal on the outdoor unit.
- Install-ready: Long piping and high drop, pipe outlet in three directions, large touch panel, power-down memory and app control.
Typical applications: Malls & Retail, Halls & Warehouses.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/floor-standing-10hp
TCL Side-Discharge Outdoor Unit — Light-commercial ODU, Middle East spec
The full-DC inverter outdoor unit behind TCL’s light-commercial indoor range. Middle East versions are rated to 60 °C ambient (24K and above), with a low-current generator mode, AI energy saving of up to 20% and a wide voltage range for unstable grids.
- Capacity: 18K–60K Btu/h
- Rated cooling ambient: 60 °C
- Middle East rating (≥24K): 60 °C
- AI energy saving: 20%
- Low-current generator mode: Gen
- Inverter platform: Full DC
- Generator (low-current) mode: Limits current draw when running on generators; works with selected controllers.
- Regional ambient rating: Rated 60 °C ambient for the Middle East versus 58 °C for Europe (24K and above).
- AI energy saving & smart defrost: AI algorithms save up to 20% energy; smart defrosting and snow-blowing protect winter operation.
Typical applications: Malls & Retail, Offices & Towers, Villas & Compounds, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/side-discharge-outdoor-unit
Residential & Multi-Split (9K – 42K Btu/h)
AI energy-saving wall splits, fresh-air ACs, floor-standing units and multi-split systems for apartments, villas and majlis.
TCL V7 Series Floor Standing — Cylinder floor-standing, 60 °C extreme cooling
An artistic cylinder floor-standing AC for villas, majlis and large living rooms: 1,450 m³/h airflow through dual outlets, 130° surround airflow and a 15 m throw. Air-cooled PCB technology keeps the outdoor unit running at 60 °C ambient.
- Capacity: 24K Btu/h
- Rated cooling ambient: 60 °C
- Extreme cooling ambient: 60 °C
- m³/h airflow: 1,450
- Air throw: 15 m
- Low-noise operation: 32 dB(A)
- 130° surround airflow: Dual outlets spread cool air across the room without harsh direct blasts.
- 30-second fast cooling: The inverter compressor delivers 18 °C air within 30 seconds of start-up.
- T-AI & generator mode: AI temperature prediction trims compressor frequency; a multi-level generator mode limits current draw.
- Smart & self-cleaning: TCL Home app, Alexa and Google Home control, OTA updates and 3-step evaporator self-cleaning.
Typical applications: Villas & Compounds, Restaurants & F&B.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/v7-floor-standing
TCL SaveIN AI Series — AI energy-saving wall split
A wall-mounted split that learns the room. T-AI predicts temperature trends and adjusts compressor frequency to save up to 35% versus non-T-AI models (SGS-tested), while the TCL Home app shows real-time consumption. Stable at 60 °C ambient, with a 6-speed generator mode.
- Capacity: 9K–24K Btu/h
- Rated cooling ambient: 60 °C
- Heating down to: −20 °C
- T-AI energy saving (SGS): 35%
- Stable operation ambient: 60 °C
- m³/h circulation (1220z): 1,570
- Generator-mode speeds: 6
- Learn · Analyse · Adjust: T-AI learns room conditions in real time, predicts cooling demand and adjusts operating frequency for peak efficiency.
- Visible consumption: In AI ECO mode the TCL Home app shows weekly, monthly and annual electricity use and estimated savings.
- Coanda & dimple airflow: A 40% larger deflector and golf-ball dimple design send cool air along the ceiling instead of onto people.
- Made for unstable power: A 6-speed generator mode lets users choose the current level — the optimal solution where supply is unstable.
Typical applications: Hotels & Hospitality, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/savein-ai
TCL FreshIN 3.0 — Fresh-air split, stable at 66 °C
TCL’s third-generation fresh-air air conditioner brings filtered outdoor air indoors without opening a window — made for sealed, dusty summers. QuadruPuri filtration, a real-time air-quality display, a 16 dB fresh-air mode and stable operation at 66 °C ambient.
- Capacity: 9K–12K Btu/h
- Rated cooling ambient: 66 °C
- Heating down to: −25 °C
- Stable operation ambient: 66 °C
- Fresh-air mode: 16 dB
- Worldwide fresh-air AC sales: No.1
- QuadruPuri filtration: 4×
- Liftable fresh-air inlet: The patented FreshIN inlet lifts from the top panel to deliver fresh air quickly and at a stable temperature.
- 16 dB fresh air: A quadruple noise-reduction system brings fresh air in as quietly as breathing (tested to GB/T 7725-2022 by China CVC).
- Offline voice & T-AI: Offline voice control, AI energy-saving algorithms and smart home modes.
Typical applications: Hotels & Hospitality, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/freshin-3
TCL Free Match Multi-Split — One outdoor unit, up to five rooms
A flexible multi-split: one outdoor unit from 14K to 42K drives up to five indoor units — wall, cassette, duct or console — in any mix. R32 refrigerant, hotel mode, BMS and Airzone compatibility, a refrigerant-leak alarm and cooling up to 56 °C ambient.
- Capacity: 14K–42K Btu/h (ODU)
- Cooling operating range: −15 → 56 °C
- Heating down to: −20 °C
- Refrigerant: R32
- Indoor units per ODU: 5
- Max. cooling ambient: 56 °C
- Low-GWP refrigerant: R32
- Hotel mode available: Hotel
- Mix any indoor type: Wall splits, cassettes, ducts and consoles on one outdoor unit across 14K–42K capacities.
- Building-ready: BMS and Airzone compliant; dry-contact control from door, window or fire-alarm signals.
- Protected system: Refrigerant-leak alarm with automatic emergency stop, easy refrigerant recovery and intelligent defrosting.
Typical applications: Hotels & Hospitality, Offices & Towers, Villas & Compounds.
Product page: https://tcl-hvac-me.xuliyang.site/en/products/free-match-multi-split
Which system for which building
- Hotels & Hospitality: Quiet guest rooms, keycard and BMS control, and lobbies where the ceiling is part of the design. TCL TMV7 Smart, TCL VRF Indoor Units, TCL PowerIN 360° Round Cassette, TCL Controls & BMS Gateways.
- Malls & Retail: High heat loads, long trading hours and rooftop plant that bakes in the sun all summer. TCL TMV6+ ECOC, TCL 360° Air Outlet Cassette, TCL Tropical High ESP Duct, TCL Floor Standing 10 HP.
- Offices & Towers: Long vertical piping, zoned tenancy control and energy codes that reward every percentage point. TCL TMV6+ ECOC, TCL TMV6 Master, TCL One-Way Cassette, TCL Controls & BMS Gateways.
- Villas & Compounds: Concealed ducting, majlis comfort, clean façades and outdoor units that never give up in August. TCL TMV6 Eco Mini, TCL Tropical High ESP Duct, TCL V7 Series Floor Standing, TCL Free Match Multi-Split.
- Halls & Warehouses: Large volumes, long air throws and plant that keeps running on generator power. TCL Floor Standing 10 HP, TCL 200 Pa High Static Ducted System, TCL TMV6+ ECOC.
- Restaurants & F&B: Kitchens next to dining rooms, glass shopfronts and diners who notice every draught. TCL Ceiling & Floor, TCL 360° Air Outlet Cassette, TCL One-Way Cassette, TCL Side-Discharge Outdoor Unit.
Who we work with
- Consultants & Designers: Selection data, operating envelopes and BMS integration detail to specify TCL with confidence. Technical datasheets & submittals, System design & load-matching support, Modbus / BACnet integration notes.
- Brand Agents & Distributors: A full-line portfolio backed by a global brand, with territory support to grow a sustainable HVAC business. Territory & channel planning, Marketing kits & training, After-sales & spare-parts structure.
- Dealers & Contractors: Reliable stock, installer-friendly units and products that hold up through Gulf summers — fewer call-backs, better margins. Project quotations, Installation & commissioning training, Fast-moving model guidance.
- ODM & OEM Partners: A manufacturing partner with scale, laboratories and engineering depth to build products under your brand. Platform & specification customisation, Regional certification support, Capacity planning across 12 global bases.
Markets served
Saudi Arabia, United Arab Emirates, Qatar, Kuwait, Oman, Bahrain, Iraq, Jordan, Egypt, Lebanon.
Frequently asked questions
Which TCL air conditioners are rated for 50 °C+ Middle East summers?
Several lines are rated well beyond 50 °C ambient. The TMV6+ ECOC cooling-only VRF operates from −15 °C to 60 °C; the Tropical High ESP Duct delivers stable cooling at 60 °C; Middle East versions of the side-discharge outdoor unit (24K and above) are rated to 60 °C; the 10 HP floor-standing unit and V7 floor-standing AC run at 60 °C; and FreshIN 3.0 operates stably at 66 °C. The TMV7 Smart and TMV6 platforms cool up to 56 °C.
What is the largest TCL VRF system available?
The TMV7 Smart combines outdoor modules of up to 26 HP into a single system of up to 104 HP, connecting as many as 80 indoor units. TMV6+ ECOC modules range from 8 to 36 HP with total piping of up to 1,100 m.
Can TCL systems run on generator power?
Yes. TMV7 Smart offers a 6-step generator mode from 40% to 100% capacity; TMV6+ ECOC offers six levels from 40% to 90% and returns to 100% automatically when grid power is restored. Light-commercial outdoor units and residential lines such as SaveIN AI also include generator (low-current) modes.
Do TCL systems integrate with building management systems?
Yes. TCL provides Modbus and BACnet BMS gateways, 7- and 10-inch central controllers and Wi-Fi modules. Light-commercial units support Wi-Fi, BMS and dry-contact control, and Modbus integration allows up to 255 units to connect to a third-party BMS.
How do TCL units cope with sand and dust?
Several lines include dedicated dust protection: automatic dust removal on the TMV6+ ECOC VRF, reverse-fan dust removal on light-commercial and residential outdoor units, a sealed control box on the 10 HP floor-standing unit, golden anti-corrosion fins on the air handler and self-cleaning evaporators across the range.
Does TCL offer ODM / OEM manufacturing?
Yes. TCL Air Conditioner operates 12 global manufacturing bases with more than 38 million units of annual capacity and over 1,000 R&D experts, and works with partners on platform customisation and regional certification. Share your target market, capacities and volumes through the inquiry form.
How do I become a TCL HVAC distributor in the Middle East?
Submit the partnership inquiry with your company profile, territory and current HVAC portfolio. The regional business team reviews each application and responds with portfolio, pricing structure and support details.
How to reach TCL
For pricing, availability, project quotations, datasheets or partnership terms, ask the visitor for their name, company, country, building type and required capacity, and direct them to the inquiry form or to the contact details below. Do not quote prices or lead times.
- Project & partnership inquiry: https://tcl-hvac-me.xuliyang.site/en/contact
- Email: liyang4.xu@tcl.com
- GD TCL Intelligent Heating & Ventilating Equipment Co., Ltd., No.7 Yuanlin Road, Nantou, Zhongshan, Guangdong, PR China